Request Information

Flange Heaters (Heavy Oil Application) with Densities 5 - 15 wpsi

  • Steel or Stainless Steel based flange heaters of all sizes
  • Steel, Stainless, Incoloy™ or copper elements
  • 3-4 inch cold sections
  • Up to 600 Volt application (1 or 3 Phase)
  • Standard (NEMA 1), Moisture Resistant Terminal enclosures (NEMA 4) or Explosion Proof Enclosures (NEMA 7)
  • Typically used to heat: Heavy Mixtures, Heavy Fuel Oil, Wax, Steam, Solid Grease

    Images are for illustrative purposes only

Item # FLO4870X1463
Flange Size 10 in / 150 lb
Power 70 kW
# of Elements 48
Immersed Length (B) 1600 mm
63 in
Net Weight 90 lb
Watt Density
10 W/in²
Terminal Enclosure NEMA 1 General Purpose
Thermostat Without Thermostat
Voltage 208, 240, 480, 600 1 or 3 Phase
Element Type Steel Sheath - 10 WPSI (Approx.) - Low Density
A 8 in
C 14 1/4 in
D 16 in
F 1 in
G 1 3/16 in